CN EN RU
Домашняя страница > Центр продукции > Fume & dust treatment > Equipment and System for Removal of Dioxin in the Fly Ash from Waste Incineration
описание продукта
Equipment and System for Removal of Dioxin in the Fly Ash from Waste Incineration
Equipment and System for Removal of Dioxin in the Fly Ash from Waste Incineration Equipment and System for Removal of Dioxin in the Fly Ash from Waste Incineration
Equipment and System for Removal of Dioxin in the Fly Ash from Waste Incineration
The destruction system of fly ash dioxins from waste incineration can break down and remove dioxins in fly ash, and can operate continuously and stably. The dioxins removal rate can be over 99% and the dioxin content in treated fly ash is controlled within 50ng-TEQ/kg (as per dry basis of fly ash) which can meet the requirements of Technical Specification for Pollution Control of Fly Ash From Municipal Solid Waste Incineration (HJ1134-2020). As a key link in utilization of fly ash resources, this system’s process and throughput can be customized according to clients’ demands.
  • Типоразмерный ряд:ENFI-De-PCDD/Fs-1/5/10/20/30
  • Производительность:Customized capacity of 0-30t/d (as per dry basis of fly ash)
  • Область применения:Location: indoor installation; Plant voltage class: AC: 380V/220V, 50H; Requirements of nitrogen quality: pressure≮0.6MPa, purity≮99.99%.
Контактный телефон+86 13521339794
Получение цены
Оставление сообщений онлайн
enfi.cemsa@gmail.com
Преимущества и особенности
  • Continuous operation; low-temperature treatment; dioxins destruction rate>99%.
Принцип работы
Under the anaerobic environment, in a suitable temperature range and residence time, the Cl chemical bond in solid-phase PCDD/Fs can break down into inorganic Cl-, realizing dioxins destruction.
Технические параметры
Technical Data Sheet
Maximum design temperature: 550℃
Normal working temperature: 350-500℃
Oxygen content during normal operation: ≤130ppm
Furnace tube section size Diameter: φ300mm-φ1500mm
Heating method: Horizontal/annular heating
Temperature control: Temperature control in groups
Furnace temperature fluctuation range: ±2℃/2H (indicated by temperature controller)
Furnace tube rotating speed: 0.5-2r/min, continuously variable, VSD;
Furnace body inclination angle: 0–1°;
Installed power: 20~600Kw
Достижения применения
Pilot test...
Pilot test of Xiangyang Domestic Waste Incineration Plant, fly ash throughput: 0.25t/d
Соответственная рекомендация
Complete Zinc oxide Off-gas Desulfurization Equipment
Complete Zinc oxide Off-gas Desulfurization Equipment
Intelligent Combustion Control System(ICC)
Intelligent Combustion Control System(ICC)
An ultra-low-pollutants off-gas emission system
An ultra-low-pollutants off-gas emission system
High-speed rotary atomizer
High-speed rotary atomizer